Filtration, regulation and treatment of compressed air, Page 9
Product sorting
List of products
AAFA 1" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F04 with 1/2" female thread connection. The filter is equipped with a clogging...
Float valve for condensate discharge from compressed air system working on float principle. Version AOK16B for internal mounting of filter vessels using 1/2" thread.
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-780. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...
AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
Hankison filter cartridge for HF series air filter type F06. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Electronic condensate drain from a compressed air system up to 16 bar, operating on a timed valve switching. External mounting on the filter body using a 1/2" thread. Simple...
Water-oil separators chemically separate oil and solid impurities from the condensate from the water, which can then be discharged into the waste. They contribute to a high...
AAFB coarse filter in 3/8" design to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable...
Replacement filter cartridge PFM for filter with filtration capacity up to 0,1 um and working pressure 16 bar. Operating temperature up to 150°C. Made of borosilicate microfibers.
Bypass piping for MDX400 to 1800 condensation dryers for easy replacement of filter cartridges without the need for shutdown.Simple assembly during dryer installation. The...
Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection with 3/4" internal pipe threads. The design allows a flow rate of up to 1867 l/min....
Removes mechanical dirt up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F07 with 3/4" female thread connection. The filter is equipped with a clogging...
Regulator for pressure reduction of compressed air and other non-volatile and non-toxic gases with G 1" inlet and outlet pressure regulation 0,5 - 25 Bar. Maximum inlet pressure...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F08 with 1" female thread connection. The filter is equipped with a clogging indicator and an...
Futura Treatment Units - Compressed Air Pressure Regulators, Designed for compressed air with or without oil and for neutral gases, Designed according to ATEX II 2G2D, Maximum...
Hankison filter cartridge for SF series air filter type F04. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Futura Treatment Units - Compressed Air Pressure Regulators, Designed for compressed air with or without oil and for neutral gases, Designed according to ATEX II 2G2D, Maximum...
Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-510. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...
Replacement filter cartridge PFI1 for filter with filtration capacity up to 1 um and working pressure 12 bar. Operating temperature up to 150°C. Made of stainless steel strainer.
Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....
Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-780. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...
AAFP basic filter in 1/4" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-780 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...
Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...
Regulators for pressure reduction of compressed air and other non-volatile and non-toxic gases. Maximum inlet pressure 40 bar, various outlet pressures, operating temperature...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
Hankison filter cartridge for HF series air filter type F07. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F08 with 1" female thread connection. The filter is equipped with a clogging...
Water-oil separators chemically separate oil and solid impurities from the condensate from the water, which can then be discharged into the waste. They contribute to a high...
Hankison filter cartridge for SF series air filter type F07. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-2160. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-1000. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...
Hankison filter cartridge for HF series air filter type F10. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
AAFP 1" basic filter for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and designed...
AAFP basic filter in 2" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...